MD-5 Glass Density Comparator

Comparative Density Measurement for Glass and Solid Materials

MD-5 provides controlled sink-float comparative density measurement for glass and other non-porous solid materials, combining precision temperature monitoring, adjustable magnetic stirring and integrated heating.

Designed according to GB/T 14901-2008

MD-5 glass density comparator Laboratory Density Measurement

System Overview

Controlled Density Measurement by the Sink-Float Method

Measurement Range 1.1–3.3 g/cm³
Test Method GB/T 14901-2008
Materials Glass, ceramics and non-porous solids
Measurement Method Sink-float comparative density

After the required temperature is reached, the system can calculate and display the density value of the reference sample.

Key Features

Measurement and Control Functions

01

1.1–3.3 g/cm³ Range

Density measurement range for glass and other non-porous solids.

02

0.001°C Resolution

Dual-probe digital temperature monitoring for controlled testing.

03

≤0.08°C Bath Difference

Specified horizontal and vertical water-bath temperature difference.

04

0–1500 rpm Stirring

Continuously adjustable magnetic stirring.

05

Integrated Heating

Electrical heating supports controlled temperature adjustment.

06

Laboratory Configuration

Dedicated system configuration for comparative density testing.

Technical Specifications

MD-5 Measurement and Instrument Data

Density measurement range
1.1–3.3 g/cm³
Temperature display range
25 ± 15°C
Temperature resolution
0.001°C
Heating rate
Better than 0.2 ± 0.08°C/min
Magnetic stirring speed
0–1500 rpm, continuously adjustable
Horizontal bath temperature difference
≤0.08°C
Vertical bath temperature difference
≤0.08°C
Power supply
AC 220 V
Power
350 W
Dimensions
530 × 370 × 550 mm (L × W × H)
Weight
Approx. 15 kg

System Configuration

Integrated Laboratory Components

  • 5000 mL glass water bath
  • 40 W ring lamp
  • Magnetic stirrer — 0–1500 rpm continuously adjustable; 25 W
  • Electrical heater with variable resistor — 300 W
  • Five 100 mL glass test tubes
  • Dual-probe high-precision digital thermometer

Applications

Density Measurement Use Cases

  • Glass density measurement
  • Glass laboratory quality control
  • Comparative material-density testing
  • Ceramic apparent-density testing
  • Non-porous solid material testing
  • Research and quality-control laboratories